The belt magnetic separator is not directly usable for production. First of all, we must ensure that the iron remover can operate normally. Therefore, after installing the belt magnetic separator, it is necessary to do the corresponding debugging work, in order to help everyone to be easier and smoother. Complete the debugging task, let’s introduce the debugging method before the belt magnetic separator is turned on:
1. Before starting the machine, it is necessary to check whether the oil level of the belt magnetic separator is not at the upper limit of the oil mark. And sequentially send power to each switch, and open the excitation circuit, check the fan to confirm that the wind flow is outward, and the flow meter is accurate. If there is a problem, it is necessary to adjust the wiring of the fan and the special pump appliance.
2. If the iron removal effect of the belt magnetic separator is not good, adjust the front and rear distances of the lifting height or the belt magnetic separator and the head roller.
3. Always observe the voltmeter of the belt magnetic separator and the reading of the ammeter is normal and cannot exceed its rated value.
4. Check the electrical insulation performance of the coil and the motor. After the requirements are met, the power can be tested.
5. Before the belt magnetic separator is operated, the insulation resistance between the winding and the magnet housing should be tested through a megger. The value should be within 10 megohms. Confirm that the wiring of the field winding is correct and reliable. Can be put into production.