Suspended permanent magnet iron remover belt damage how to repair quickly- RCYD
the email of beltmagnets factory

HomeBlog › Suspended permanent magnet iron remover belt damage how to repair quickly

Suspended permanent magnet iron remover belt damage how to repair quickly

The suspended permanent magnet iron remover may have an emergency situation in which the conveyor belt suddenly breaks during use. If the electromagnetic iron remover has a belt damage, you may choose to repair it yourself in case of less damage or emergency. But do you know how to repair the conveyor belt quickly? Here is a brief introduction to the steps for repairing the suspended permanent magnet separator.
1. Using an electric stripper to cut a 3 mm deep repair area in each 40 mm area on both sides of the crack of the suspended permanent magnet iron remover belt, and cut 5 cm at the same time, and perform steps 2 to 4 Repair operation.
2. Apply the primer to the repair area of ​​the suspended permanent magnet iron remover belt, mix and pour the special repair glue, and pour it into the repair area to make it smooth. Here to remind everyone, there are two points to note: (1) each group of repair glue is 3.5 meters (400g); after applying the primer for 15min, apply glue again.
3. Apply special repair rubber while the repair glue is horizontally slippery, and repeat the rolling twice by special rollers.
Fourth, in order to reduce the standby time of the suspended permanent magnet iron remover, the upper part can be heated and repaired by the heating blanket (this step can be omitted when the temperature exceeds 15 degrees Celsius).
5. Apply a certain weight to the surface of the suspended permanent magnet iron remover belt to make the bonded surface flat.

 

suspended permanent magnet